Topic: pole discordance(discrepancy)

Post Info
Koperal
Status: Offline
Posts: 50
Date:
pole discordance(discrepancy)
Permalink  
 

unit perlindungan pada EHV BREAKER..fungsi sebagai single pole breaker trip..kemudian terus lock out 3 phase trip..



__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
benda ni duduk kat mane? kat tiang/pylon or kat MSB?

__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

unit protection yg ade pada internal breaker atau di control panel pada breaker single pole..kebanyakkan ade pada 275,500kv breaker..



__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
Contoh breaker single pole?

__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

breaker single pole bermaksud setiap phase mempunyai breaker dengan menggunakan Gas circuit breaker (sf6) operation sequence:hydraulics,peneumatics,spring charge..

jadi satu feeder ade 3 breaker untuk setiap phase R,Y,B menggunakan pole disrepancy supaya apabila close breaker mesti ketiga-tiga phase close serentak jika salah satu tidak close maka pole discrepancy akan bertindak dalam masa 2saat utk lock out ketiga-tiga phase..begitu juga bile dalam keadaan open breaker konsep yg sama..lock out ketiga-tiga phase..



__________________
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
berapa percentage accuracy dia.. lock-out tu energize secara mekanikal or elektrikal?

__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

Dia tidak ade accurancy %..cume setting pada time to lockout mesti krng drp 2 second yg dipratikkan oleh TNB...lock out pada mekanikal n elektrik protection..pada breaker..



__________________
Rekrut
Status: Offline
Posts: 8
Date:
Permalink  
 

letak gambar lah bos,,,,baru snng cite....mana org pernah tgok benda menatang ni,,,,



__________________
dulu,kini dan selamanya elektrik...........
Laksamana Muda
Status: Offline
Posts: 1145
Date:
Permalink  
 
motor burn wrote:

letak gambar lah bos,,,,baru snng cite....mana org pernah tgok benda menatang ni,,,,


 LIKE!



__________________

Henry Ford
Coming together is a beginning. Keeping together is progress. Working together is success.

MFC Commissioner [OFFICIAL] CODE: 1601

IEEE Members CODE: 92905849

@Bahaya Elektrik 

@CMC Student Branch 

@Standard Gaji Chargeman 

Rekrut
Status: Offline
Posts: 4
Date:
Permalink  
 

bro, kalau tak salah, single pole breaker nih mostly applied by  TNB, scheme untuk 275kv & 500kV. untuk OHL ngan Cable feeder jer kan



__________________
Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

hanye utk HV breaker 275/500KV tnb station..

gambarP1030573.JPG

gambar dia atas menunjukkan 275kv Breaker GIS..gas circuit breaker..single pole..



__________________
Rekrut
Status: Offline
Posts: 4
Date:
Permalink  
 
GMBAR GIS TU AMIK DARI PMU MNA?


__________________
Rekrut
Status: Offline
Posts: 4
Date:
Permalink  
 
pole discordance hanyalah scheme...bknnye breaker...susah org yg buka tread ni nk post gmbr...cume gune relay pole discordance,utk CB jnis individual closing n tripping..


__________________
Koperal
Status: Offline
Posts: 50
Date:
Permalink  
 

PMU salak south 275kv..gmbr tu nak menunjukkan single breaker yg mengunakan pole discrodance..ade juge breaker siemens yg mengunkan pole discodence pada internal protection pada breake jd dia dah siapkan scheme pole discrodence dalam internal beraker...yg gambar di atas tadi breaker TSG dari XIAN dimana pole discrodence relay shceme pada control panel..

konsep 1 dia bile satu  atau dua phase tak close..breaker akan louckout(trip) open 3phase..

Konsep 2 bile satu atau dua phase tak trip..breaker akan louckout(trip)..

setting standart time 2second..

bergantung pada setting time untul autoreclose relay..pole discrodence mesti lebih dari setting time autoreclose utk single phase trip..1Pole atau 1+3pole..



__________________
 